Bored pier inspection in Edmondson Park

Depth, diameter and cage, confirmed while the bore is still open.

  • After boring and cage placement, before concrete
  • About 1 hour on site
  • Report within 24 hours
Price your Edmondson Park inspectionSend the address and the stage you are at.

Fully licensed & accredited

Stage1 of 7
When to bookAfter boring and cage placement, before concrete
Time on siteAbout 1 hour on site
Inspected againstAS 2870, AS 3600, the geotechnical report and the engineer's footing design

What is included in a Edmondson Park bored piers inspection

  • Pier positions and spacing against the footing plan
  • Pier diameter checked at the top of each hole
  • Depth against the engineer's design and the soil report
  • Founding material at the base where visible
  • Reinforcement cage size, laps and starter bars
  • Cover to the cage and centralisers
  • Hole cleanliness, spoil and loose material
  • Standing water or seepage before the pour
  • Steel projection into the slab or beam
  • Termite and service penetrations near piers
  • Set-out against the site plan and boundaries
  • Records and photographs for the engineer where required
Why it matters here

Bored piers inspections on Edmondson Park builds

Piers turn up on Edmondson Park lots where the footing has to reach past fill, and on land that spent half a century as an army camp there is fill in places you would not predict. Depth is the whole exercise, and concrete ends any chance of confirming it. Every photograph here was taken in Austral, roughly six kilometres north west of Edmondson Park and in the same growth corridor. We would rather name the suburb than let another job read as local.

What we find at this stage in Edmondson Park

  • Bore shallower than the engineering requires
  • Cage off centre, leaving uneven cover
  • Spoil or water sitting in the base
  • Cage lifted clear of the bottom
  • Reinforcement unsupported ahead of the pour
Grading required, Austral, Edmondson Park
Grading required, Austral
Sample findings

Sample defects found during our bored piers inspections in Edmondson Park

Annotated findings from Bored piers inspections on Edmondson Park builds. Client addresses withheld.

Site not graded, recorded during a frame inspection in Austral
Site not graded, Austral
Slab edges and rebates, recorded during a frame inspection in Austral
Slab edges and rebates, Austral
Vapour barrier sections missing, recorded during a frame inspection in Austral
Vapour barrier sections missing, Austral
Bottom plates appear fine, recorded during a frame inspection in Austral
Bottom plates recorded as satisfactory, Austral

The other stages of a Edmondson Park build

  1. Slab pre-pour inspection in Edmondson Park2Slab pre-pourThe day before the pour, steel and formwork complete
  2. Frame inspection in Edmondson Park3FrameOnce frame and trusses are up and the roof is on, before lining
  3. Lock-up (pre-plaster) inspection in Edmondson Park4Lock-up (pre-plaster)After roof, cladding and external doors, before plaster
  4. Fixing inspection in Edmondson Park5FixingAfter mouldings, doors and joinery, before the painter
  5. Waterproofing inspection in Edmondson Park6WaterproofingAfter the membrane is applied and before any tile is laid
  6. Pre-handover (PCI) inspection in Edmondson Park7Pre-handover (PCI)Two to three weeks before your handover date

All construction stage inspections in Edmondson Park →

Guides

Construction stage guides for Edmondson Park

All guides →

Book a bored piers inspection in Edmondson Park

Instant online pricing, or talk to the booking team on 1300 471 805.

FAQ

Bored piers inspections in Edmondson Park: common questions

How long are you on site for this?

Under an hour on a typical lot, longer where there are many piers or the site is spread out.

What if a bore is short?

The measured depth goes in beside the required depth. The remedy is between your builder and their engineer, and the report gives them the figure.

Do you certify the footing?

No. We record against the engineering. Certification is an engineer's function and the report says when one is needed.

Why does the army camp history matter?

Because filled and disturbed ground behaves differently from natural ground, and the engineering for a lot is drawn from a soil report that takes account of it. That is what we check against.

Will the builder mind?

Rarely. Pier depth is the concreter's own record too, and a second set of measurements on the day protects everybody.

What should I send across?

Your lot engineering, with pier depths, diameters and positions marked.

CallGet a Free Quote